Recreational diving with self-contained underwater breathing devices is gaining popularity worldwide as a sport and leisure activity.1 People living with type 1 diabetes mellitus (PLT1D) are no exception, although the exact prevalence of scuba diving in this population is difficult to determine. However, available estimations suggest that about 1% of people engaged in recreational diving are using insulin treatment.2
Historically, diabetes mellitus, especially insulin-treated, has been described as an absolute contraindication for diving.3 Excluding individuals with diabetes mellitus from common activities such as diving may contribute to heightened anxiety and diabetes-related distress, underscoring the clinical and social relevance of this issue. However, based on observational data collected in the United States by the Divers Alert Network, the presence of background diabetes mellitus constituted only a relative contraindication for those without significant co-morbidities or long-term complications.3 Despite minor differences between existing recommendations, several scientific bodies, including the South Pacific Underwater Medicine Society, the United Kingdom Diving Medical Committee, and the Australian Diabetes Society, have also endorsed scuba diving for individuals with diabetes mellitus who meet specific suitability criteria.1 Furthermore, a specific protocol based on serial capillary blood glucose (BG) measurements before and after each dive has been developed, and criteria focused on glycaemic control, the presence of complications, and hypoglycaemia awareness were established for defining eligibility of PLT1D for diving.1
Diving is associated with a wide spectrum of health risks, ranging from mild or moderate conditions, such as ear barotrauma and seasickness to potentially life-threatening events, including arterial gas embolism, decompression illness, and pulmonary barotrauma. These arise from changes in ambient pressure, gas composition, and environmental factors, such as low temperatures, which challenge various adaptive mechanisms of human physiology.1 For individuals with diabetes mellitus, additional risks include impaired nitrogen elimination, increased susceptibility to decompression illness, and fluctuations in BG levels due to pressure, cold, dehydration, and stress.1,4 Human studies indicate that exposure to a hyperbaric environment can influence glucose homeostasis.1 In individuals with type 2 diabetes mellitus, simulated hyperbaric conditions have been shown to improve BG concentrations and peripheral insulin sensitivity, while one study reported that hyperbaric oxygenation enhanced residual insulin secretion in PLT1D.1 Real-world data further suggest that BG levels tend to decline during diving, likely due to altered insulin requirements and sensitivity, increased physical activity, and the physiological effects of the hyperbaric environment on glucose tolerance.1
Regarding diving activities among PLT1D, the primary concern is the risk of hypoglycaemia, especially in those with impaired awareness. Furthermore, symptoms consistent with hypoglycaemia could be confused with those originating from other factors related to diving. Indeed, fatigue could result from the expended effort during a dive, while reduced cognitive focus or lethargy could arise from cold stress.5 Similarly, confusion or mental absence could be the consequence of nitrogen narcosis, while malaise or other physical compromise might result from decompression illness.5
Although avoidance of hypoglycaemia is imperative among PLT1D practicing diving, the risk of severe hyperglycaemia should also be minimised. Recommendations suggest frequent pre-dive BG measurements, but this strategy is apparently insufficient to eliminate the risk of hypoglycaemia during diving. On the other hand, although continuous glucose monitoring (CGM) nowadays represents the diagnostic standard of care for PLT1D, its accuracy during diving activities is still a matter of debate.
This commentary aims to summarize the existing data on accuracy, durability, and underwater performance of different CGM devices among PLT1D engaged in diving and to call for additional research in the field.
A summary of studies evaluating the use of various CGM devices during scuba diving among PLT1D is presented in Table 1. While these studies provide valuable insights into device accuracy, durability, and underwater performance, several limitations affect their reproducibility and comparability. First, the relatively small sample sizes reduce the reliability of data interpretation. Second, heterogeneity in research methodologies, environmental conditions, and accuracy assessment parameters, along with missing data on device survival in some studies, limits precise cross-study comparisons. Moreover, none of the studies evaluated the reliability or latency of CGM alarms during dives, a factor potentially critical for the timely detection and management of hypoglycaemia. Finally, in certain cases, studies were supported by CGM manufacturers, which may have introduced reporting bias.
Table 1 Summary of the Results of Studies Assessing the Use of Continuous Glucose Monitoring Devices During Scuba Diving Among People Living with Type 1 Diabetes Mellitus
|
Since none of the currently available CGM devices have met the criteria for nonadjunctive use during diving, further technological improvements are necessary. Future research should involve robust, head-to-head trials with larger and more diverse participant populations, conducted under varying environmental conditions. Such studies would enable the collection of more reliable data on device accuracy and durability, and help explain the previously reported discrepancies in underwater performance.10 Additionally, meticulous evaluation of CGM alarm performance during dives is urgently needed, as this feature is critical for the timely detection of life-threatening events, such as severe hypoglycaemia and diabetic ketoacidosis. Future CGM development should also address factors that may degrade device function, including repeated changes in pressure and humidity, a wider glycaemic range, and greater glycaemic variability.10 However, given that the underwater environment presents significant logistical and safety challenges for clinical research, investigations in this setting should be limited to small-scale studies primarily aimed at advancing our understanding of physiological mechanisms.
Although existing CGM devices do not yet meet the standards for reliable and safe standalone use underwater, they may still serve as a valuable adjunct for planning and monitoring dives in PLT1D, provided they are used alongside standard safety protocols requiring serial capillary BG measurements before and after each dive. While CGM use can enhance safety during diving activities, users must be clearly informed about its limitations, and diving without adherence to established safety protocols should be strongly discouraged.
In conclusion, technological advances have significantly improved the quality of life for people living with diabetes mellitus, and CGM has the potential to further enhance safety for PLT1D engaging in diving. Nonetheless, unresolved challenges, particularly in underwater data transmission and accuracy, mean that its application still requires caution.
Author Contributions
All authors made a significant contribution to the work reported, whether that is in the conception, study design, execution, acquisition of data, analysis and interpretation, or in all these areas; took part in drafting, revising or critically reviewing the article; gave final approval of the version to be published; have agreed on the journal to which the article has been submitted; and agree to be accountable for all aspects of the work.
Funding
There is no funding to report.
Disclosure
Professor Nikolaos Papanas reports personal fees from Galenica, Bayer, Boehringer, Sanofi, Lilly, Menarini, AstraZeneca, Vianex, and Elpen, outside the submitted work. The authors declare that they have no other competing interests for this work.
References
1. Koufakis T, Karras SN, Mustafa OG, Karangelis D, Zebekakis P, Kotsa K. Into the deep blue sea: a review of the safety of recreational diving in people with diabetes mellitus. Eur J Sport Sci. 2020;20:1–16. doi:10.1080/17461391.2019.1606286
2. Adolfsson P, Ornhagen H, Jendle J. Accuracy and reliability of continuous glucose monitoring in individuals with type 1 diabetes during recreational diving. Diabetes Technol Ther. 2009;11:493–497. doi:10.1089/dia.2009.0017
3. Jendle JH, Adolfsson P, Pollock NW. Recreational diving in persons with type 1 and type 2 diabetes: advancing capabilities and recommendations. Diving Hyperb Med. 2020;50:135–143. doi:10.28920/dhm50.2.135-143
4. Melamed Y, Shupak A, Bitterman H. Medical problems associated with underwater diving. N Engl J Med. 1992;326:30–35. doi:10.1056/NEJM199201023260105
5. Petri NM, Andrić D. Differential diagnostic problems of decompression sickness-examples from specialist physicians’ practices in diving medicine. Arch Med Res. 2003;34:26–30. doi:10.1016/S0188-4409(02)00458-7
6. Bonomo M, Cairoli R, Verde G, et al. Safety of recreational scuba diving in type 1 diabetic patients: the Deep Monitoring programme. Diabetes Metab. 2009;35:101–107. doi:10.1016/j.diabet.2008.08.007
7. Lormeau B, Pichat S, Dufaitre L, et al. Impact of a sports project centered on scuba diving for adolescents with type 1 diabetes mellitus: new guidelines for adolescent recreational diving, a modification of the French regulations. Arch Pediatr. 2019;26:161–167. doi:10.1016/j.arcped.2018.12.006
8. Gamarra E, Cimino E, Fazi A, et al. Accuracy of a real-time continuous glucose monitoring system (rtCGM) during consecutives scuba diving in type 1 diabetes (T1D): the “Diabete Sommerso 2019” experience. Diabetes Technol Ther. 2020;22:A–128.
9. Herold P, Weh D. Performance of continuous glucose monitoring systems under hyperbaric conditions an exploratory study to increase diabetic divers’ safety. Preprints 2023:2023070268.;
10. Gamarra E, Careddu G, Fazi A, et al. Continuous glucose monitoring and recreational scuba diving in type 1 diabetes: head-to-head comparison between Free Style Libre 3 and Dexcom G7 performance. Diabetes Technol Ther. 2024;26:829–841. doi:10.1089/dia.2024.0126